V2000-c Rfid Access Control User Manual [extra Quality] Jun 2026

| Terminal | Label | Connection | Wire Gauge (AWG) | | :--- | :--- | :--- | :--- | | 1 | +12V | Power Supply Positive (10-14V DC) | 18-22 | | 2 | GND | Power Ground / Common Negative | 18-22 | | 3 | NO | Normally Open (Magnetic Lock) | 18 | | 4 | COM | Common (Lock Relay) | 18 | | 5 | NC | Normally Closed (Electric Strike - Fail Secure) | 18 | | 6 | PUSH | Exit Button Signal (Short to GND to activate) | 22 | | 7 | SEN | Door Contact Sensor (Magnetic Reed Switch) | 22 | | 8 | AL+ | Alarm Output (+) | 22 | | 9 | AL- | Alarm Output (-) | 22 | | 10 | +12V | Reader Power (For external reader – rarely used) | 22 | | 11 | DATA0 | Wiegand Data 0 (For external reader) | 22 | | 12 | DATA1 | Wiegand Data 1 (For external reader) | 22 |

[Current Date] Prepared For: Security System Administrators / End Users Subject: Functional Overview, Installation Guidelines, and Operational Procedures V2000-c Rfid Access Control User Manual

Security isn't just about locks; it's about administration. The manual highlights how to change the default Master Programming Code. | Terminal | Label | Connection | Wire

Nach oben