Eplan P8 2.0 Validation Codel -
| Codel | Description | Likely Cause | Quick Fix | |-------|-------------|--------------|-------------| | | Page number not unique | Two pages share the same number | Renumber pages via Options > Renumber pages | | 20011 | Double device tag | Same DT used on different components | Use Project > Synchronization to reassign tags | | 20145 | Connection without target | A wire or cable end is not connected to any terminal or device | Trace the connection and add a target or delete it | | 30221 | Missing function template | A PLC address has no corresponding symbol in the layout | Update the PLC library or manually assign the symbol | | 40017 | Invalid potential definition | Voltage values conflict (e.g., 24V and 230V on same net) | Split the net or use a potential separator | | 55003 | Macro placeholder not resolved | A macro contains variables that were never defined | Edit macro properties and fill all placeholders |
Eplan will process the project and display a window. This report lists every issue found, organized by severity: Eplan P8 2.0 Validation Codel