Ogg-01184 Expected 4 Bytes But — Got 0 Bytes In Trail
This creates a new trail file (e.g., increments sequence from Reposition the Pump to the start of this new sequence: ALTER PUMP , EXTSEQNO , EXTRBA Use code with caution. Copied to clipboard Common Causes to Investigate Network Failures
If the file is partially recoverable, use logdump to write a clean trail: ogg-01184 expected 4 bytes but got 0 bytes in trail
: Review the report files for the upstream process (the one writing the trail) to see if it abended or was forcefully killed, which might have led to an incomplete write. Check for Disk Space This creates a new trail file (e
If the source Extract or Pump is the one failing, force it to start a new trail file to skip the corrupted segment: ALTER [process_name], ETROLLOVER . : The process checkpoint (RBA) is positioned beyond
: The process checkpoint (RBA) is positioned beyond the physical size of the trail file. Network or Filesystem Issues
After rolling over, you may need to reposition the downstream process to the new sequence number.